Skip to content
Renovation & DIY

How to install a shower head and choose a water-saving one

Replacing a shower head takes a few hand tools and a roll of thread seal tape. This guide covers removal, installation, the federal and WaterSense flow limits, and the minimum flow rating your shower valve may call for.

By The Homefield Journal Editors Reviewed

Two hands threading a round chrome shower head onto the shower arm above a tiled tub surround, with the shower handle below

What do you need before you replace a shower head?

Most shower heads thread onto the end of the shower arm, the short pipe that comes out of the wall, so replacing one does not involve opening the wall or touching the valve. Moen's guide for a shower filter that installs on the shower arm the same way a head does lists an adjustable wrench and thread seal tape. Kohler's installation guide for its rain showerheads lists sealant tape and a strap wrench, along with a thin-bladed screwdriver for cleaning the screen washer later on.

Keep a soft cloth nearby as well. Kohler's guide asks you to use a clean wrench and to take care not to mar the finish when you remove a showerhead, and a cloth wrapped around the connection protects chrome or painted finishes from the jaws of an ordinary wrench.

Before you buy a new head, look up the instruction sheet for your shower valve by its brand and model number, because some valves are rated for a minimum shower head flow.

How do you take off the old shower head?

Make sure the shower valve is fully off, then grip the old head and turn it counterclockwise, the opposite of the clockwise direction Moen gives for threading a fitting onto the shower arm. Moen's instructions note that you may need a wrench if the head is too tight. If you use one, wrap the connection in your cloth first and turn slowly so the arm is not forced.

Once the head is off, Moen's instructions have you peel away the old thread seal tape and clean the threads on the pipe. The EPA's WaterSense program also suggests checking the washer or O-ring inside the showerhead and replacing it if needed while you make this repair.

Hands wrapping white thread seal tape around the threads of a chrome shower arm, with the old shower head resting on a towel below
Moen's instructions call for peeling off the old tape, cleaning the threads and wrapping new thread seal tape tightly, about 3 to 5 times.

How do you install the new shower head?

The steps below follow the order in Kohler's rain showerhead guide and the taping details in Moen's shower filter instructions. Where the sheet packed with your new head gives different directions, follow that sheet.

  1. With the shower valve off, clean the threads on the shower arm so that no old tape or debris is left on them.
  2. Turn the water on for a moment with the head removed to flush any debris through the shower arm, then turn it off again.
  3. Wrap new thread seal tape tightly around the shower arm threads. Moen suggests approximately 3 to 5 wraps.
  4. Check that the washer or screen washer is seated inside the inlet of the new head. Kohler's guide reinstalls its screen washer with the tapered end facing out.
  5. Thread the head onto the arm by turning it clockwise, starting by hand so the threads engage straight.
  6. Tighten the connection securely with a clean strap wrench, as Kohler's guide directs.
  7. Turn on the water and check all connections for leaks.

If your new head comes with its own shower arm, Kohler's guide adds a few steps: apply sealant tape to the threads at both ends of the arm, tighten the arm into the elbow in the wall with a strap wrench, seal the back of the wall flange with plumbers putty or another sealant, and secure the flange with its setscrew before the head goes on.

How much water does a shower head use?

The EPA's WaterSense program says showering accounts for nearly 17 percent of residential indoor water use, which comes to nearly 40 gallons per day for the average family. Federal conservation standards set the upper limit on flow. Under 10 CFR 430.32, showerheads manufactured after January 1, 1994, may use at most 2.5 gallons per minute when measured at a flowing pressure of 80 pounds per square inch. The same rule requires the flow-restricting insert to be mechanically retained at the factory, so that removing it takes a force of 8 pounds or more, and Kohler's guide tells you not to attempt to remove the flow control when you clean the screen washer.

Shower heads that earn the WaterSense label must show that they use no more than 2.0 gallons per minute, and they are independently certified for spray force, spray coverage and pressure compensation, which the EPA describes as a minimum flow across a range of household water pressures. The agency estimates that the average family could save 2,700 gallons of water a year by installing WaterSense labeled showerheads, along with more than 330 kilowatt hours of electricity, because less water has to be heated. Its Shower Better page puts the savings from replacing one showerhead at more than $75 a year in energy and water costs. The EPA also notes that in many areas, utilities offer rebates and vouchers that lower the price of a labeled showerhead, so check with your water utility before you buy.

A fingertip rubbing across the rubber spray nozzles of a chrome shower head as water runs through it
Kohler's care guide clears clogged spray holes by running water through the head and rubbing a finger back and forth across its face.

Does your shower valve need a minimum flow rate?

Some shower valves are automatic compensating valves, and their makers rate each one for a minimum shower head flow. Kohler's guide tells you to choose an automatic compensating valve with the appropriate minimum flow rating to ensure the valve will provide safety at the lowest flow rates. Moen's valve instruction sheets show how much these ratings vary within a single brand, with some of its valve lines listed for showerheads rated at 1.5 gallons per minute or higher, one at 1.3 gallons per minute or higher, and another at 2.5 gallons per minute or higher.

Before you choose a water-saving head, find the minimum flow printed on your valve's instruction sheet and pick a head rated at or above that number. Kohler's guide also carries a scald warning and asks you to set the water temperature at or below 120 degrees Fahrenheit by following the adjustment procedure in the valve's own guide. If you cannot identify the valve behind your handle, a plumber can look it up for you before the new head goes on.

How do you keep the new shower head working well?

Kohler's care guide gives a simple routine for spray holes that clog with debris or mineral buildup. Run water through the head and firmly rub your finger back and forth across the spray holes on its face. If the spray does not improve, remove the head with a clean wrench, carefully pry up the edge of the screen washer with a thin-bladed screwdriver, clean the washer and reinstall it with the tapered end out. Apply fresh sealant tape to the shower arm threads before you put the head back on.

For the finish, Kohler recommends a mild detergent such as liquid dishwashing soap with warm water, and advises against abrasive cleaners that may scratch or dull the surface. Read the label of any cleaner to confirm it is safe for the material, test it on an inconspicuous area first and do not let it sit or soak on the surface. You can add the spray hole check to your home maintenance checklist so it happens on a regular schedule.

What if the new shower head leaks or drips?

A few drops from the face of the head after you turn the shower off usually come from water left inside it. Kohler's guide notes that some water may remain in the showerhead after each use, and that tilting the head to drain prevents dripping.

Water that seeps from the threaded joint while the shower runs means the tape on the shower arm is not sealing. Turn the water off, remove the head, peel away the tape, wrap the threads again with 3 to 5 tight turns as Moen suggests, and reinstall the head. A steady drip that continues long after the shower is off is a sign that the valve itself is leaking, and our guide on how to fix a leaking bathtub faucet walks through washer and cartridge repairs. For more projects in this room, browse our bathroom guides.

When to call a pro

When a licensed plumber should take over

A licensed plumber can take over when the job goes past the threaded connection at the end of the shower arm, such as a loose or damaged arm, a leak inside the wall or a valve you cannot identify. Licensing rules for plumbers vary by state, and your state or local licensing board can confirm a plumber's license.

  • The shower arm moves in the wall, is cracked, or leaks where it meets the wall.
  • You cannot find the brand, model or minimum flow rating of your shower valve.
  • The water temperature needs to be set at the valve and its adjustment steps are unclear to you.
  • The connection still leaks after you have cleaned and retaped the threads.

Common questions

Do you need thread seal tape on a shower head?

The Moen and Kohler instructions used for this guide both call for thread seal tape on the shower arm threads before the head or filter goes on. Moen suggests approximately 3 to 5 tight wraps. Check the sheet packed with your new head, since its directions take precedence.

What is the maximum flow rate for a shower head?

Federal standards in 10 CFR 430.32 limit showerheads manufactured after January 1, 1994, to 2.5 gallons per minute at a flowing pressure of 80 pounds per square inch. Showerheads with the EPA's WaterSense label use no more than 2.0 gallons per minute.

Can you remove the flow restrictor from a shower head?

The federal standard requires the flow-restricting insert to be mechanically retained at the point of manufacture, and Kohler's guide tells you not to attempt to remove the flow control when you clean the screen washer. Leave it in place.

Will a low-flow shower head work with any shower valve?

Automatic compensating valves are rated for a minimum shower head flow, and Kohler advises choosing a valve with the appropriate minimum flow rating so it provides safety at the lowest flow rates. Moen lists ratings from 1.3 to 2.5 gallons per minute across its valve lines, so check the sheet for yours.

Sources

Sources checked on November 23, 2026.

  1. Showerheads, WaterSense, U.S. Environmental Protection Agency : Share of indoor water use from showering, the 2.5 and 2.0 gallons per minute figures, performance certification, savings estimates, rebates and the washer or O-ring tip.
  2. Shower Better, WaterSense, U.S. Environmental Protection Agency : Water, electricity and cost savings from replacing one showerhead with a WaterSense labeled model.
  3. 10 CFR 430.32, Energy and water conservation standards, Electronic Code of Federal Regulations : Maximum flow of 2.5 gallons per minute at 80 psi for showerheads manufactured after January 1, 1994, and retention of the flow-restricting insert.
  4. Installation and Care Guide, Rain Showerheads, Kohler : Tools, installation order, flushing the shower arm, strap wrench, screen washer, minimum flow rating of compensating valves, scald warning and care.
  5. Shower Filter Installation Guide INS13016, Moen : Removing a shower head from the shower arm, cleaning off old tape, 3 to 5 wraps of thread seal tape and threading clockwise.
  6. One-Handle Tub/Shower Valve Installation Guide INS10177B, Moen : Minimum showerhead flow ratings for Moen automatic compensating valve lines and taping the shower arm before the head goes on.

Keep reading

Renovation & DIY

All in Renovation & DIY

How to replace a light switch safely

Swapping a worn single-pole wall switch is a manageable job once the power is off and tested. This guide covers how to identify your switch, make each connection the way the manufacturer specifies, and recognize wiring that belongs to an electrician.